Sign In | Join Free | My qualitytoyschina.com
China IRONMAN TECHNOLOGY CO., LTD logo
IRONMAN TECHNOLOGY CO., LTD
Better late than never.
Site Member

6 Years

Home > Honeywell PLC Module >

51204172-125 ANALOG OUPUT 16 Honeywell PLC Module MU-TAOY22 Long Service Life

IRONMAN TECHNOLOGY CO., LTD
Contact Now

51204172-125 ANALOG OUPUT 16 Honeywell PLC Module MU-TAOY22 Long Service Life

  • 1
  • 2

Brand Name : Honeywell

Model Number : 51204172-125

Place of Origin : USA

MOQ : 1 PCS

Price : USD

Payment Terms : T/T

Delivery Time : 3-5 days

Condition : Original New

Warranty : 12 Months

Shipping term : DHL/TNT/UPS/FEDEX etc.

Quality : Orginal and brand new

Type : Eletronic Component

Design : Plan & 3D Model & Structral Design

Contact Now

Ironman Technology Co.,LTD

About us:

We specializes in automation parts and industrial controls, PLCS,DCS,Module/Board,Power supply,Controller, etc.We maintains an inventory of new and obsolete parts utilized in all areas of the manufacturing and industrial sectors.


Featured Brand:
● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER

● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more !


51204172-125 HONEYWELL MU-TAOY22 ANALOG OUPUT 16 honeywell plc

Lead time:3-5 days

New with one year warranty

51204172-125 ANALOG OUPUT 16 Honeywell PLC Module MU-TAOY22 Long Service Life

The Process Manager (PM), Advanced Process Manager (APM) and High Performance Process Manager (HPM) are Honeywell’s leading TotalPlant Solution (TPS) system control and data acquisition devices for industrial process applications. They represent a powerful combination of cost-effective Honeywell controllers which can be applied to solve a broad range of industrial process control problems. The PM, APM, HPM, and EHPM offer highly flexible I/O (input/output) functions for both data monitoring and control. One of the unique features of this family of controllers is its common set of Input/Output Processors (IOPs) and Field Termination Assemblies (FTAs). All IOPs and FTAs are usable by all three controllers (with only minor exceptions).

This specification and technical data sheet provides information on PM, APM, HPM, and EHPM IOPs and FTAs. Please refer to the following specification and technical data sheets for information about each controller: • PM03-400 - Process Manager Specification and Technical Data • AP03-500 - Advanced Process Manager Specification and Technical Data • HP03-500 - High Performance Process Manager Specification and Technical Data • EHPM03-600 - Enhanced High Performance Process Manager Specification

3. Functional Des cription 3.1. Functional Overview I/O Processors, along with Field Termination Assemblies (FTAs), perform input and output scanning and processing on all field PM/APM/HPM/EHPM I/O

A redundant I/O Link is standard for maximum security. Optionally, High Level Analog Input, Smart Transmitter Interface, Analog Output, Digital Input and Digital Output processors can be redundant. I/O processing is performed separately from control processing functions so that I/O scan rates are completely independent of I/O quantity, controller loading, processing, and alarming. This partitioning of functions allows more efficient use of advanced Control Processor capability and provides for future I/O expansion. A variety of I/O processors are available for the PM controllers: • Analog Input–High Level (16 points) • Analog Input–Low Level (8 points) • Analog Input–Low Level Multiplexer (32 points) • Smart Transmitter Multivariable Interface (16 points) • Analog Output (8 points) • Analog Output (16 points) • Serial Device Interface (16 points—2 ports) • Serial Interface (32 arrays, 2 ports)* • Pulse Input (8 points) • Digital Input (32 points) • Digital Input 24 Vdc (32 points) • Digital Input Sequence of Events (DISOE) (32 points)

• Digital Output (16 points) • Digital Output (32 points) • Foundation Fieldbus (127 slots, 4 Fieldbus segments)** * APM, HPM, and EHPM only ** HPM and EHPM only Any mix of the above I/O processors can be selected for a PM/APM/HPM/EHPM controller. This can be any combination of single and/or redundant (HLAI, STI, AO, DI and DO) pairs, up to a total of 40. Even with the maximum complement of 80 physical IOPs, there is no impact on control or communication performance. In a redundant IOP configuration, control automatically transfers to the backup I/O processor during board replacement or failure. While a separate FTA of a given type is required to handle varying field wiring signal levels, identical I/O Processors can usually be used. This I/O approach simplifies system hardware selection and minimizes spare parts requirements. For example, one Digital Input Processor can handle 24 Vdc, 120 Vac, 125 Vdc or 240 Vac, depending on the FTA selected. Analog Input High and low level analog input (HLAI + LLAI - 8) processors both perform signal conversion and conditioning functions: • PV Source (Auto, Manual, Substituted) • PV Clamping • EU Conversion • PV Value Status • PV Filter (Single Lag) • Bad PV • PV Hi/Lo • PV HiHi/LoLo • PV Rate-of-Change +/- • Software Calibration • Low PV Cutoff


We have good price on AB PLC,Omron PLC and Honeywell C200,C300,model number such like TC/TK/MC/CC/511/512/513/514 and some FC series goods,
If you have other enquiry,pls feel free to let me know.

Product Tags:

tc iah161

      

mc paih03

      
Quality 51204172-125 ANALOG OUPUT 16 Honeywell PLC Module MU-TAOY22 Long Service Life wholesale

51204172-125 ANALOG OUPUT 16 Honeywell PLC Module MU-TAOY22 Long Service Life Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: IRONMAN TECHNOLOGY CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)